Data Center: Difference between revisions
m Update a infobox machine for version 0.5.1b |
Brammigamer (talk | contribs) Updated all values for the Data Center for update 3. |
||
Line 10: | Line 10: | ||
}} | }} | ||
| Workers = 6 | | Workers = 6 | ||
| Electricity = 0 - | | Electricity = 0 - 4.08 MW | ||
| Computing = 0 - + | | Computing = 0 - +192 | ||
| MaintenanceIII = | | MaintenanceIII = 3.8 | ||
| Footprint = 18x11 | | Footprint = 18x11 | ||
| BoostByUnity = no | | BoostByUnity = no | ||
Line 19: | Line 19: | ||
| Variants = | | Variants = | ||
}} | }} | ||
The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide | The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 4 [[TFlop]]s of [[Computing Power]]. A single server rack consists of 12 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage. | ||
The Data Center requires {{infoicon|Electricity}}, {{infoicon|Chilled Water|new=yes}}, and {{infoicon|Maintenance III|new=yes}}. An amount of them is shown following table and expression. | The Data Center requires {{infoicon|Electricity}}, {{infoicon|Chilled Water|new=yes}}, and {{infoicon|Maintenance III|new=yes}}. An amount of them is shown following table and expression. | ||
Line 31: | Line 31: | ||
! {{infoicon|Electricity}}<br/>(KW) | ! {{infoicon|Electricity}}<br/>(KW) | ||
|- | |- | ||
| 0 || 0.0 || | | 0 || 0.0 || 3.8 || 0 | ||
|- | |- | ||
| 1 || 0. | | 1 || 0.59 || 4.6 || 85 | ||
|- | |- | ||
| 2 || 1. | | 2 || 1.17 || 5.4 || 170 | ||
|- | |- | ||
| 4 || | | 4 || 1.76 || 6.9 || 340 | ||
|- | |- | ||
| 8 || 4. | | 8 || 4.10 || 10.0 || 680 | ||
|- | |- | ||
| 12 || | | 12 || 5.86 || 13.0 || 1020 | ||
|- | |- | ||
| 16 || 8. | | 16 || 8.20 || 16.0 || 1360 | ||
|- | |- | ||
| 24 || | | 24 || 11.7 || 22.0 || 2040 | ||
|- | |- | ||
| 32 || | | 32 || 15.8 || 28.0 || 2720 | ||
|- | |- | ||
| 40 || | | 40 || 19.9 || 35.0 || 3400 | ||
|- | |- | ||
| 48 || 24.0 || | | 48 || 24.0 || 41.0 || 4080 | ||
|} | |} | ||
'''General expression''' | '''General expression''' | ||
:{{infoicon|Chilled Water|new=yes}} = ( | :{{infoicon|Chilled Water|new=yes}} = (0.50 × Number of Server Racks) {{time}} | ||
:{{infoicon|Maintenance III|new=yes}} = (0.77 × Number of Server Racks + 3.8) {{time}} | |||
:{{infoicon|Maintenance III|new=yes}} = (0. | :{{infoicon|Electricity}} = (85 × Number of Server Racks) KW | ||
:{{infoicon|Electricity}} = ( | note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. | ||
When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance). | |||
{{Footer Infobox}} | {{Footer Infobox}} |
Latest revision as of 17:44, 16 May 2025

Construction | |
Workers | ![]() |
Electricity | ![]() |
Computing | ![]() |
Maintenance | ![]() ![]() |
Footprint | 18x11 |
Required Research | Datacenter |
Boost by Unity | Not Available |
Designation | General Machines ![]() |
The Data Center is a machine containing up to 48 server racks. Each server rack is able to provide 4 TFlops of Computing Power. A single server rack consists of 12 Servers and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.
The Data Center requires Electricity, File:ChilledWater.png Chilled Water, and File:MaintenanceIII.png Maintenance III. An amount of them is shown following table and expression.
Server Rack | File:ChilledWater.png Chilled Water ( / 60 ![]() |
File:MaintenanceIII.png Maintenance III ( / 60 ![]() |
Electricity (KW) |
---|---|---|---|
0 | 0.0 | 3.8 | 0 |
1 | 0.59 | 4.6 | 85 |
2 | 1.17 | 5.4 | 170 |
4 | 1.76 | 6.9 | 340 |
8 | 4.10 | 10.0 | 680 |
12 | 5.86 | 13.0 | 1020 |
16 | 8.20 | 16.0 | 1360 |
24 | 11.7 | 22.0 | 2040 |
32 | 15.8 | 28.0 | 2720 |
40 | 19.9 | 35.0 | 3400 |
48 | 24.0 | 41.0 | 4080 |
General expression
- File:ChilledWater.png Chilled Water = (0.50 × Number of Server Racks) / 60
- File:MaintenanceIII.png Maintenance III = (0.77 × Number of Server Racks + 3.8) / 60
- Electricity = (85 × Number of Server Racks) KW
note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance).