Data Center: Difference between revisions
mNo edit summary |
fix |
||
(17 intermediate revisions by 9 users not shown) | |||
Line 1: | Line 1: | ||
{{Infobox machine | {{Infobox machine | ||
| Name = Data Center | | Name = Data Center | ||
| Description = Datacenter is used to host server racks that you add to it. Each added server rack provides computing as a resource that can be used on your island. Computing is used in advanced machines such as [[Assembly (Robotic)|robotic assemblers]] or [[Microchip Machine|microchip makers]]. It is worth noting that each server rack has its [[ | | Description = Datacenter is used to host server racks that you add to it. Each added server rack provides computing as a resource that can be used on your island. Computing is used in advanced machines such as [[Assembly (Robotic)|robotic assemblers]] or [[Microchip Machine|microchip makers]]. It is worth noting that each server rack has its [[Electricity|power]], [[Chilled Water|cooling]], and [[Maintenance|maintenance]] demands. However, some people say that all it does is to persist and search in a vast collection of pictures of cats and memes - we were not able to debunk this. | ||
| Recipe = | | Recipe = | ||
{{Machine Recipe | {{Machine Recipe | ||
| Input1Name = Construction Parts | | Input1Name = Construction Parts IV | ||
| Input1Qty = | | Input1Qty = 120 | ||
| Input2Name = Electronics | | Input2Name = Electronics III | ||
| Input2Qty = | | Input2Qty = 40 | ||
}} | }} | ||
| Workers = 6 | | Workers = 6 | ||
| Electricity = 0 - | | Electricity = 0 - 4.08 MW | ||
| Computing = 0 - + | | Computing = 0 - +192 | ||
| MaintenanceIII = | | MaintenanceIII = 3.8 | ||
| Footprint = 18x11 | | Footprint = 18x11 | ||
| Research = | | BoostByUnity = no | ||
| Designation = | | Research = Datacenter (research) | ||
| Designation = Production | |||
| Variants = | | Variants = | ||
}} | }} | ||
{{ | The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 4 TFlops of [[Computing]]. A single server rack consists of 12 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage. | ||
The Data Center requires {{infoicon|Electricity}}, {{infoicon|WaterChilled|link=Chilled Water|text=Chilled Water|new=yes}}, and {{infoicon|Maintenance3|text=Maintenance III|link=Maintenance III|new=yes}}. An amount of them is shown following table and expression. | |||
{|class="wikitable" style="text-align: right" | |||
|+ Upkeep cost of Data Center | |||
|-style="text-align: center" | |||
! Server Rack | |||
! {{infoicon|WaterChilled|link=Chilled Water|text=Chilled Water|new=yes}}<br/>({{time}}) | |||
! {{infoicon|Maintenance3|text=Maintenance III|link=Maintenance III|new=yes}}<br/>({{time}}) | |||
! {{infoicon|Electricity}}<br/>(KW) | |||
|- | |||
| 0 || 0.0 || 3.8 || 0 | |||
|- | |||
| 1 || 0.59 || 4.6 || 85 | |||
|- | |||
| 2 || 1.17 || 5.4 || 170 | |||
|- | |||
| 4 || 1.76 || 6.9 || 340 | |||
|- | |||
| 8 || 4.10 || 10.0 || 680 | |||
|- | |||
| 12 || 5.86 || 13.0 || 1020 | |||
|- | |||
| 16 || 8.20 || 16.0 || 1360 | |||
|- | |||
| 24 || 11.7 || 22.0 || 2040 | |||
|- | |||
| 32 || 15.8 || 28.0 || 2720 | |||
|- | |||
| 40 || 19.9 || 35.0 || 3400 | |||
|- | |||
| 48 || 24.0 || 41.0 || 4080 | |||
|} | |||
{{ | '''General expression''' | ||
:{{infoicon|WaterChilled|link=Chilled Water|text=Chilled Water|new=yes}} = (0.50 × Number of Server Racks) {{time}} | |||
:{{infoicon|Maintenance3|text=Maintenance III|link=Maintenance III|new=yes}} = (0.77 × Number of Server Racks + 3.8) {{time}} | |||
:{{infoicon|Electricity}} = (85 × Number of Server Racks) KW | |||
note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. | |||
When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance). | |||
{{Footer Infobox}} |
Latest revision as of 19:56, 25 June 2025

Construction | |
Workers | ![]() |
Electricity | ![]() |
Computing | ![]() |
Maintenance | ![]() ![]() |
Footprint | 18x11 |
Required Research | Datacenter |
Boost by Unity | Not Available |
Designation | Production ![]() |
The Data Center is a machine containing up to 48 server racks. Each server rack is able to provide 4 TFlops of Computing. A single server rack consists of 12 Servers and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.
The Data Center requires Electricity, Chilled Water, and
Maintenance III. An amount of them is shown following table and expression.
Server Rack | ![]() ( / 60 ![]() |
![]() ( / 60 ![]() |
Electricity (KW) |
---|---|---|---|
0 | 0.0 | 3.8 | 0 |
1 | 0.59 | 4.6 | 85 |
2 | 1.17 | 5.4 | 170 |
4 | 1.76 | 6.9 | 340 |
8 | 4.10 | 10.0 | 680 |
12 | 5.86 | 13.0 | 1020 |
16 | 8.20 | 16.0 | 1360 |
24 | 11.7 | 22.0 | 2040 |
32 | 15.8 | 28.0 | 2720 |
40 | 19.9 | 35.0 | 3400 |
48 | 24.0 | 41.0 | 4080 |
General expression
Chilled Water = (0.50 × Number of Server Racks) / 60
Maintenance III = (0.77 × Number of Server Racks + 3.8) / 60
- Electricity = (85 × Number of Server Racks) KW
note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance).
Recipes
Below are all the recipes which this building is capable of producing. Note that some of them may be locked behind Research and not immediately available in your game.
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
* Only available in the Supporter Edition |