Data Center: Difference between revisions
mNo edit summary |
m Fix icons |
||
Line 21: | Line 21: | ||
The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 4 [[TFlop]]s of [[Computing Power]]. A single server rack consists of 12 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage. | The '''Data Center''' is a machine containing up to 48 server racks. Each server rack is able to provide 4 [[TFlop]]s of [[Computing Power]]. A single server rack consists of 12 {{infoicon|Server|text=Servers|new=yes}} and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage. | ||
The Data Center requires {{infoicon|Electricity}}, {{infoicon|Chilled Water|new=yes}}, and {{infoicon|Maintenance III|new=yes}}. An amount of them is shown following table and expression. | The Data Center requires {{infoicon|Electricity}}, {{infoicon|WaterChilled|link=Chilled Water|text=Chilled Water|new=yes}}, and {{infoicon|Maintenance3|text=Maintenance III|link=Maintenance III|new=yes}}. An amount of them is shown following table and expression. | ||
{|class="wikitable" style="text-align: right" | {|class="wikitable" style="text-align: right" | ||
Line 27: | Line 27: | ||
|-style="text-align: center" | |-style="text-align: center" | ||
! Server Rack | ! Server Rack | ||
! {{infoicon|Chilled Water|new=yes}}<br/>({{time}}) | ! {{infoicon|WaterChilled|link=Chilled Water|text=Chilled Water|new=yes}}<br/>({{time}}) | ||
! {{infoicon|Maintenance III|new=yes}}<br/>({{time}}) | ! {{infoicon|Maintenance3|text=Maintenance III|link=Maintenance III|new=yes}}<br/>({{time}}) | ||
! {{infoicon|Electricity}}<br/>(KW) | ! {{infoicon|Electricity}}<br/>(KW) | ||
|- | |- | ||
Line 55: | Line 55: | ||
'''General expression''' | '''General expression''' | ||
:{{infoicon|Chilled Water|new=yes}} = (0.50 × Number of Server Racks) {{time}} | :{{infoicon|WaterChilled|link=Chilled Water|text=Chilled Water|new=yes}} = (0.50 × Number of Server Racks) {{time}} | ||
:{{infoicon|Maintenance III|new=yes}} = (0.77 × Number of Server Racks + 3.8) {{time}} | :{{infoicon|Maintenance3|text=Maintenance III|link=Maintenance III|new=yes}} = (0.77 × Number of Server Racks + 3.8) {{time}} | ||
:{{infoicon|Electricity}} = (85 × Number of Server Racks) KW | :{{infoicon|Electricity}} = (85 × Number of Server Racks) KW | ||
note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. | note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. | ||
When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance). | When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance). | ||
{{Footer Infobox}} | {{Footer Infobox}} |
Revision as of 13:59, 25 June 2025

Construction | |
Workers | ![]() |
Electricity | ![]() |
Computing | ![]() |
Maintenance | ![]() ![]() |
Footprint | 18x11 |
Required Research | Datacenter |
Boost by Unity | Not Available |
Designation | Production ![]() |
The Data Center is a machine containing up to 48 server racks. Each server rack is able to provide 4 TFlops of Computing Power. A single server rack consists of 12 Servers and can be assembled instantly in the Data Center as long as there are enough Servers in the player's storage.
The Data Center requires Electricity, Chilled Water, and
Maintenance III. An amount of them is shown following table and expression.
Server Rack | ![]() ( / 60 ![]() |
![]() ( / 60 ![]() |
Electricity (KW) |
---|---|---|---|
0 | 0.0 | 3.8 | 0 |
1 | 0.59 | 4.6 | 85 |
2 | 1.17 | 5.4 | 170 |
4 | 1.76 | 6.9 | 340 |
8 | 4.10 | 10.0 | 680 |
12 | 5.86 | 13.0 | 1020 |
16 | 8.20 | 16.0 | 1360 |
24 | 11.7 | 22.0 | 2040 |
32 | 15.8 | 28.0 | 2720 |
40 | 19.9 | 35.0 | 3400 |
48 | 24.0 | 41.0 | 4080 |
General expression
Chilled Water = (0.50 × Number of Server Racks) / 60
Maintenance III = (0.77 × Number of Server Racks + 3.8) / 60
- Electricity = (85 × Number of Server Racks) KW
note that the numbers in the expressions of the chilled water and maintenance III are approximations and are based on a linear regression of the values in the table. When the Data Center has no server, it is idle and thus consumes even less maintenance (only 1.3 maintenance).
Recipes
Below are all the recipes, which this building is capable of producing. Note, that some of them may be locked behind Research, and not immediately available in your game.
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
* Only available in the Supporter Edition |