Cooling Tower (Large): Difference between revisions

From Captain of Industry Wiki
Jump to: navigation, search
L32 (talk | contribs)
m Footer Infobox
NaK (talk | contribs)
Update for version 0.5.1b
Line 15: Line 15:
| Footprint    = 9x9
| Footprint    = 9x9
| BoostByUnity  = yes
| BoostByUnity  = yes
| Research      = Nuclear Reactor
| Research      = Power Generation IV
| Designation  = Water Extraction & Processing
| Designation  = Water Extraction & Processing
| Variants      = [[Cooling Tower]]
| Variants      = [[Cooling Tower]]
}}
}}
The '''Cooling Tower (Large)''' is a much higher throughput and physically much larger variant of the [[Cooling Tower]] which allows for the conversion of {{infoicon|Steam Hi}}, {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}} byproducts into {{infoicon|Water}}. As the ratio of {{infoicon|Water}} to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained therein. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate.
The '''Cooling Tower (Large)''' is a much higher throughput and physically much larger variant of the [[Cooling Tower]] which allows for the conversion of {{infoicon|Steam (Super)}}, {{infoicon|Steam Hi}}, {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}} byproducts into {{infoicon|Water}}. As the ratio of {{infoicon|Water}} to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained from {{infoicon|Steam Lo}}, and {{infoicon|Steam Depleted}}. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate.


It can process the resulting steam output from up to 8 [[Arc Furnace II]] machines or 4 [[Exhaust Scrubber]]s. Conversely, it takes exactly 3 of these to handle the steam output of a single [[Nuclear Reactor]] with 3x output.
It can process the resulting steam output from up to 16 [[Arc Furnace II]] machines or 4 [[Exhaust Scrubber]]s. Conversely, it takes exactly 3 of these to handle the steam output of a single [[Nuclear Reactor]] with 3x output.
{{recipe define
{{recipe define
  | Input1Name  = Steam (Super)
  | Input1Qty  = 16
  | Time        = 10
  | Output1Name = Water
  | Output1Qty  = 8
}}{{recipe define
   | Input1Name  = Steam Hi
   | Input1Name  = Steam Hi
   | Input1Qty  = 16
   | Input1Qty  = 16
   | Time        = 10
   | Time        = 10
   | Output1Name = Water
   | Output1Name = Water
   | Output1Qty  = 12
   | Output1Qty  = 10
}}{{recipe define
}}{{recipe define
   | Input1Name  = Steam Lo
   | Input1Name  = Steam Lo
Line 40: Line 46:
   | Output1Name = Water
   | Output1Name = Water
   | Output1Qty  = 12
   | Output1Qty  = 12
}}{{Footer Infobox}}
}}
{{Footer Infobox}}

Revision as of 12:20, 16 May 2023

Cooling Tower (Large)
T2

Improves Water efficiency of a power plant by recovering some Steam back to Water.
Construction
80
+
200
Workers 4
ElectricityNone
MaintenanceNone
Footprint9x9
Required ResearchPower Generation IV
Boost by UnityAvailable
DesignationWater Extraction & Processing 
VariantsCooling Tower

The Cooling Tower (Large) is a much higher throughput and physically much larger variant of the Cooling Tower which allows for the conversion of Steam (Super), Steam (High), Steam (Low), and Steam Depleted byproducts into Water. As the ratio of Water to all types of steam is 1:1, the Cooling Tower (Large) thus recovers 75% of the Water contained from Steam (Low), and Steam Depleted. Compared to the regular Cooling Tower, this marks a 50% increase in the Water recovery rate.

It can process the resulting steam output from up to 16 Arc Furnace II machines or 4 Exhaust Scrubbers. Conversely, it takes exactly 3 of these to handle the steam output of a single Nuclear Reactor with 3x output.

Recipes

Below are all the recipes, which this building is capable of producing. Note, that some of them may be locked behind Research, and not immediately available in your game.

16
96
10 
60 
10
60
16
96
10 
60 
12
72
16
96
10 
60 
8
48
16
96
10 
60 
12
72