Exhaust Scrubber: Difference between revisions
No edit summary |
m remove |
||
(10 intermediate revisions by 4 users not shown) | |||
Line 5: | Line 5: | ||
{{Machine Recipe | {{Machine Recipe | ||
| Input1Name = Construction Parts II | | Input1Name = Construction Parts II | ||
| Input1Qty = | | Input1Qty = 80 | ||
}} | }} | ||
| Workers = 8 | | Workers = 8 | ||
| Electricity = | | Electricity = 200 KW | ||
| Maintenance = 4 | | Maintenance = 4 | ||
| Footprint = 8x6* | | Footprint = 8x6* | ||
| BoostByUnity = yes | |||
| Research = Exhaust Filtration | | Research = Exhaust Filtration | ||
| Designation = Waste Management | | Designation = Waste Management | ||
Line 16: | Line 17: | ||
The '''Exhaust Scrubber''' is the sole machine capable of consuming {{infoicon|Exhaust}} as an input. As a result, it can provide a significant reduction in overall {{infoicon|Air Pollution}} emitted on the island, reducing or entirely preventing {{infoicon|Population|ui=yes}} loss due to illness. | The '''Exhaust Scrubber''' is the sole machine capable of consuming {{infoicon|Exhaust}} as an input. As a result, it can provide a significant reduction in overall {{infoicon|Air Pollution}} emitted on the island, reducing or entirely preventing {{infoicon|Population|ui=yes}} loss due to illness. | ||
It produces {{infoicon|Sulfur}} as a useful byproduct which can be utilized in {{infoicon|Rubber}} or {{infoicon|Acid}} production. Sufficient {{infoicon|Steam Lo}} is also output to run one [[Low-pressure Turbine II]] which generates {{infoicon|Electricity}}. | It produces {{infoicon|Sulfur}} as a useful byproduct which can be utilized in {{infoicon|Rubber}} or {{infoicon|Acid}} production. Sufficient {{infoicon|Steam Lo}} is also output to run one [[Low-pressure Turbine II]] which generates {{infoicon|Electricity}}. {{infoicon|Carbon Dioxide}} can be used to create {{infoicon|Graphite}} or {{infoicon|Fuel Gas}} or safely dumped into the ground via the [[Gas Injection Pump]]. | ||
However, straight-up disposing of the byproducts (Sulfur via [[Burner (Solid)|Burner]] and CO<sub>2</sub> via [[Smoke Stack]]) still gives roughly 27% pollution reduction as compared to releasing the exhaust directly into the atmosphere. | |||
{{ | {| class="wikitable" style="text-align: right" | ||
|+ Pollution per 180 {{time}} of {{infoicon|Exhaust}} at version 0.5.2 | |||
|- style="text-align: center" | |||
! Way of disposing | |||
! {{infoicon|Air Pollution}} | |||
! {{infoicon|Water Pollution}} | |||
! {{infoicon|Health}} | |||
|- | |||
| style="text-align: left" | Release {{infoicon|Exhaust}} via [[Smoke Stack]] without scrubbing | |||
| 90 || - || -4.5 | |||
|- | |||
| style="text-align: left" | Scrub {{infoicon|Exhaust}} and ...<br/>Convert {{infoicon|Sulfur}} to {{infoicon|Acid}} and [[Liquid Dump|dump]] it<br/>Release {{infoicon|Carbon Dioxide}} via [[Smoke Stack]] | |||
| 42 || 72 || -9.3 | |||
|- | |||
| style="text-align: left" | Scrub {{infoicon|Exhaust}} and ...<br/>Burn {{infoicon|Sulfur}} via [[Burner (Solid)]]<br/>Release {{infoicon|Carbon Dioxide}} via [[Smoke Stack]] | |||
| 66 || - || -3.3 | |||
|- | |||
| style="text-align: left" | Scrub {{infoicon|Exhaust}} and ...<br/>Convert {{infoicon|Sulfur}} to {{infoicon|Slag}} and dump it<br/>Release {{infoicon|Carbon Dioxide}} via [[Smoke Stack]] | |||
| 42 || - || -2.1 | |||
|- | |||
| style="text-align: left" | Scrub {{infoicon|Exhaust}} and ...<br/>Convert {{infoicon|Sulfur}} to {{infoicon|Slag}} and dump it<br/>Inject {{infoicon|Carbon Dioxide}} via [[Gas Injection Pump]] | |||
| 24 || - || -1.2 | |||
|} | |||
{{Footer Infobox}} |
Latest revision as of 14:16, 23 June 2025
Construction | |
Workers | ![]() |
Electricity | ![]() |
Maintenance | ![]() ![]() |
Footprint | 8x6* |
Required Research | Exhaust Filtration |
Boost by Unity | Available |
Designation | Waste Management ![]() |
The Exhaust Scrubber is the sole machine capable of consuming Exhaust as an input. As a result, it can provide a significant reduction in overall Air Pollution emitted on the island, reducing or entirely preventing Population loss due to illness.
It produces Sulfur as a useful byproduct which can be utilized in Rubber or Acid production. Sufficient Steam (Low) is also output to run one Low-Pressure Turbine II which generates Electricity. Carbon Dioxide can be used to create Graphite or Fuel Gas or safely dumped into the ground via the Gas Injection Pump.
However, straight-up disposing of the byproducts (Sulfur via Burner and CO2 via Smoke Stack) still gives roughly 27% pollution reduction as compared to releasing the exhaust directly into the atmosphere.
Way of disposing | Air Pollution | Water Pollution | Health |
---|---|---|---|
Release Exhaust via Smoke Stack without scrubbing | 90 | - | -4.5 |
Scrub Exhaust and ... Convert Sulfur to Acid and dump it Release Carbon Dioxide via Smoke Stack |
42 | 72 | -9.3 |
Scrub Exhaust and ... Burn Sulfur via Burner (Solid) Release Carbon Dioxide via Smoke Stack |
66 | - | -3.3 |
Scrub Exhaust and ... Convert Sulfur to Slag and dump it Release Carbon Dioxide via Smoke Stack |
42 | - | -2.1 |
Scrub Exhaust and ... Convert Sulfur to Slag and dump it Inject Carbon Dioxide via Gas Injection Pump |
24 | - | -1.2 |
Recipes
Below are all the recipes, which this building is capable of producing. Note, that some of them may be locked behind Research, and not immediately available in your game.
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
![]() |
|
Planned or Proposed | |
* Only available in the Supporter Edition |