Steam (Low): Difference between revisions

From Captain of Industry Wiki
Jump to: navigation, search
Phoenixx (talk | contribs)
No edit summary
AK615 (talk | contribs)
No edit summary
 
(10 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{outdated}}
{{Infobox material
{{Infobox material
| Name         = Steam Lo
  | Name           = {{PAGENAME}}
| Type1         = Crafted material
  | Type1         = Crafted material
| State         = Fluid
  | State         = Fluid
| TransportedBy = [[Pipe]] [[[Pipe II|II]] • [[Pipe III|III]]]
  | TrackTransport = no
| StoredIn     = None
  | StoredIn       = None
| Variants      = [[Steam Hi]]<br>[[Steam Depleted]]
  | Variants      = [[Steam (Super)]]<br>[[Steam Hi]]<br>[[Steam Depleted]]
}}
}}
'''Steam Lo''' is the intermediate energy state of Steam (Higher energy state being {{infoicon|Steam Hi}} and lower energy state being {{infoicon|Steam Depleted}}.)


Steam Lo is the intermediate energy state of Steam (Higher energy state being [[Steam Hi]] and lower energy state being [[Steam Depleted]].)
Steam is produced as a byproduct of generating {{infoicon|Electricity}} in a [[High-pressure Turbine|High-Pressure Turbine]], scrubbing {{infoicon|Exhaust}}, or smelting with [[Arc Furnace II]].
 
 
Steam Lo is the product of either consuming the energy of [[Steam Hi]] in an [[High-pressure Turbine|High-Pressure Turbine]] to generate [[electricity]] or using an [[Exhaust Scrubber]] to scrub [[Exhaust|exhaust gases]] with the use of [[water]].
 
 
Steam Lo can be consumed in four ways: It turns into [[Steam Depleted]] by using it for energy production in a [[Low-pressure Turbine]] or is condensated into [[water]] in a [[Cooling Tower]] or is turned into [[Water]] and [[Brine]] in a [[Thermal Desalinator]] with the use of [[Seawater]] or is released into the atmosphere via a [[Smoke Stack]].
 
 
Steam Lo is transferred via [[Pipe]] [<nowiki/>[[Pipe II|II]] • [[Pipe III|III]]].
 
 
Although other gaseous [[:Category:Fluid products|Fluid Products]] can be stored in a [[Fluid Storage]][<nowiki/>[[Fluid Storage II|II]]], any kind of steam can NOT be stored in a [[Fluid Storage]][<nowiki/>[[Fluid Storage II|II]]]. (Though water can be stored.)


Steam Lo can be consumed in four ways:
*Turned into {{infoicon|Steam Depleted}} by using it for energy production in a [[Low-pressure Turbine]].
*Condensated into {{infoicon|Water}} in a [[Cooling Tower]].
*Turned into {{infoicon|Water}} and {{infoicon|Brine}} in a [[Thermal Desalinator]] with the use of {{infoicon|Seawater}}.
*Released into the atmosphere via a [[Smoke Stack]]. (No pollution caused)


{{recipe fetch|dir=out}}
Steam Lo is transferred via {{Variants|Pipe}}. Although most of [[:Category:Fluid products|Fluid Products]] can be stored in a {{Variants|Fluid Storage}}, any kind of steam can NOT be stored in a {{Variants|Fluid Storage}}. Instead, [[Thermal Storage]] can substantially store the steam.
{{recipe fetch|dir=in}}
{{Footer Infobox}}

Latest revision as of 08:27, 9 February 2024

Steam Lo is the intermediate energy state of Steam (Higher energy state being Steam (High) and lower energy state being Steam Depleted.)

Steam is produced as a byproduct of generating Electricity in a High-Pressure Turbine, scrubbing Exhaust, or smelting with Arc Furnace II.

Steam Lo can be consumed in four ways:

Steam Lo is transferred via Pipe [IIIII]. Although most of Fluid Products can be stored in a Fluid Storage [IIIIIIV], any kind of steam can NOT be stored in a Fluid Storage [IIIIIIV]. Instead, Thermal Storage can substantially store the steam.

Recipes

Below are all the recipes, which contain this item. Note, that some of them may be locked behind Research, and not immediately available in your game.

Production

Tier II
:
24
72
1
3
2
6
20 
60 
16
48
2
6
2
6
Tier II
:
12
36
2
6
1
3
2
6
20 
60 
16
48
6
18
2
6
4
12
Tier II
:
16
48
1
3
2
6
20 
60 
16
48
2
6
2
6
Tier II
:
16
48
1
3
2
6
20 
60 
16
48
4
12
2
6
4
12
Tier II
:
12
36
1
3
1
3
2
6
20 
60 
16
48
6
18
2
6
4
12
Tier II
:
16
48
1
3
2
6
20 
60 
16
48
2
6
2
6
Tier II
:
16
48
2
6
1
3
2
6
20 
60 
16
48
6
18
2
6
12
36
:
30
180
4
24
10 
60 
1
6
12
72
4
24
4
24
Tier I
:
4
24
10 
60 
 
6 MW
4
24
Tier II
:
8
48
10 
60 
 
12 MW
8
48
:
 
1
 
5
 
1

Consumption

Small
:
4
24
10 
60 
2
12
Large
:
16
96
10 
60 
12
72
Tier I
:
4
24
10 
60 
 
3 MW
4
24
Tier II
:
8
48
10 
60 
 
6 MW
8
48
Small
:
ACCEPTS
20
60
/ 20 

/ 60 
Large
:
ACCEPTS
200
600
/ 20 

/ 60 
:
12
72
4
24
10 
60 
12
72
4
24
:
 
1
 
4
 
1